GENERAL INFO

Cooling system to protect heat sensitive samples during homogenization

The BR-Cryo Cooling Unit is compatible with the Bead Ruptor 24 and is designed to prevent the increase of sample temperature during the homogenization process. Friction generated through the bead milling process generates heat that is imparted to the sample. In order to maintain a constant processing temperature during homogenization, the BR-Cryo passes chilled air (-100°C to -50°C) into the sample processing chamber and across the sample tubes to dissipate heat.

Samples can be maintained at a temperature ranging from 4°C to ambient thus protecting heat sensitive samples such as RNA and proteins. 

The BR-Cryo can be used to maintain a constant temperature when extracting functional enzymes or volatile small molecules.

 

Cryo Cooling Unit Process Time

Intra-tube temperature monitoring during bead mill homogenization. 2 mL Omni reinforced tubes containing five 2.8 mm ceramic beads (Cat # 19-628) were filled with 1 mL H2O and processed  at 7 m/s on the Bead Ruptor 24 for increasing time periods. Homogenization was performed with and without the use of the BR-Cryo cooling unit using liquid nitrogen as the cryo source. Intra-tube temperatures were monitored at each time point.
 

Bead Ruptor 24 Cryo Cooling Unit  Overview

Compatible with the Bead Ruptor 24
Adjustable cooling rate
Compatible with liquid nitrogen or dry ice with ethanol
BR-Cryo maintain sample temperatures from 4°C to ambient
Prevent protein degradation
Ensure RNA stability
Prevent enzyme activation
Laboratory Requirements

Compressed dry medical grade air
Compressed air  flow rate must be at 120 PSI
Liquid nitrogen or dry ice in ethanol (liquid nitrogen is preferred)

SPECIFICATIONS
Dimensions: 29.2 (high) x 34.3 (deep at base) / 20.3 (deep at top) x 22.9 wide cm
Weight: 7.2 kg
Cryo Chamber Volume:  1 L
Air Source Requirements: Compressed medical dry air (water < 5ppm)
Air Source Pressure: 120 PSI
Cooling Source: Liquid Nitrogen or dry ice in ethanol
Liquid Nitrogen Consumption: 1 L  per 5 min of homogenization time
Dry Ice Consumption: 1 L of 0.5 L ethanol + 0.5 L dry ice per 90 minutes of homogenization time
Tube Compatibility:With 1.5 mL, 2 mL and 7 mL tube carriages only. Not compatible with tube sizes >7 mL
Instrument Compatibility: BR Cryo is compatible with Bead Ruptor Elite (19-040E)
Warranty: One year
mehr