MY LABSHOP

ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit, CE IVD

ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit, CE IVD
Die Abbildung kann abweichen und Zubehör enthalten, das sich nicht im Lieferumfang dieses Artikels befindet.
  • (Klicken für mehr Informationen)
  • pdf_preview
  • pdf_preview
  • pdf_preview
  • pdf_preview

Artikelverweis:

  • 088M010100E
    TanBead Maelstrom 8 Nucleic Acid Extractor
  • 088M150100E
    TanBead Nucleic Acid Extractor Maelstrom 4810
  • 088M160100E
    TanBead Nucleic Acid Extractor Maelstrom 9610, CE IVD

 

Lieferzeit auf Anfrage
Bestell-Nr.: 3103010052 Preis: Login Haben Sie Fragen ? Rufen Sie 0043 (01) 244 28 55 oder senden Sie ein mail !
for detection of 2 Genes, N gene , ORF1AB gene , 100 Reaktionen

ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit is a real-time reverse transcription
polymerase chain reaction (RT-qPCR) test intended for qualitative detection of nucleic acid
from the SARS-CoV-2 in oropharyngeal swabs.
It can perform in only 30 Minutes on several Real Time Cyclers.

For In-vitro Diagnostic (IVD) Use Only

Minimumbestellmenge 5 Kits (5 x 100 Test)

The product contains oligonucleotide primers, fluorescent dye labeled probes and control material used in RT-qPCR
for the in vitro qualitative detection of SARS-CoV-2 RNA.

The test consists of three processes in a single tube assay:
● Reverse transcription of target RNA and Internal Control RNA to cDNA
● PCR amplification of target and Internal Control cDNA
● Simultaneous detection of PCR amplicons by fluorescent dye labelled probes.

The Kit includes all reagents needed for RTqPCR, 2 sets of primers and probes designed to detect the SARS-CoV-2 RNA in oropharyngeal
swabs and one set of primers and probes designed to detect the RNA from virus-like particles
(VLPs) of bacteriophage MS2. The MS2 RNA serves as an internal control for RNA extraction,
reverse transcription and PCR amplification.

The ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit is a one-step RT-qPCR test in a single
tube that first reverse transcribes specific RNA templates into cDNA copies and then
subsequently amplified by  Real-Time PCR System. In the process, the probe
anneals to a specific target sequence located between the forward and reverse primers. During
the extension phase of the PCR cycle, the 5’ nuclease activity of Taq polymerase degrades the
probe, causing the reporter dye to separate from the quencher dye, generating a fluorescent
signal. With each cycle, additional reporter dye molecules are cleaved from their respective
probes, increasing the fluorescence intensity. Fluorescence intensity ( FAM,ROX,HEX channel) is monitored at each PCR
cycle by  Real-Time PCR System


ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit shall be stored at -25℃ to -15℃.
mehr

Optionen:

  • 3103010061
    ANDIs Extractfree RNA Virus Transport Medium, CE/IVD
  • 3103010073
    ANDIs Extractfree RNA Virus Transport Medium, CE/IVD

 

Option von:

  • 3103010061
    ANDIs Extractfree RNA Virus Transport Medium, CE/IVD
  • 3103010073
    ANDIs Extractfree RNA Virus Transport Medium, CE/IVD