Spectralphotometer µl plus cuvette NanoReady Touch
Die Abbildung kann abweichen und Zubehör enthalten, das sich nicht im Lieferumfang dieses Artikels befindet.
Lieferzeit auf Anfrage
Bestell-Nr.: FC3100
Preis: Login Haben Sie Fragen ? Rufen Sie 0043 (01) 244 28 55 oder senden Sie ein mail !
Features
Large size color touch screen
Built-in 7-inch high-resolution color touch screen for more detection information, all operations can be done on the screen.
Wider detection range:
The 0.03 mm minimum detection path length, combined with a new generation of spectrometers, increases the maximum detection concentration to 27,500 ng/μL and the lowest detection concentration as low as 0.2 ng/μL dsDNA.
Vary models for your choice
According to different demands, you can choose different models of products, the full wavelength or the fixed wavelength, micro volume or cuvette, to meet the flexible detection needs. The cuvette module has a heating stirrer function.
Customizable wavelength
Built-in spectrometer, fixed wavelength model, can be upgraded to any wavelength configuration in the wavelength range according to your needs.
Light status prompt
The lighting strip around the test stand flashes with different states to show the detection process straightforwardly.
Android operating system
The machine has built-in operating system and detection software, without need a computer. Graphical touch operation is more in line with user friendly design and improves work efficiency.
Stable and reliable detection value
Both low concentration and ultra-high concentration of nucleic acid can be stably and accurately detected.
Specifications
Model: FC 3100
Detector: 2048-element CCD linear image sensor
Light Source: Xenon flash lamp
Minimum Sample Volume(µL): 0.5
Pathlength (nm) 0.03, 0.05, 0.1, 0.2, 1.0 auto-ranging
Wavelength Range(nm): 185-910
Wavelength Accuracy(nm): ±1
Spectral Bandwidth: ≤1.8(FWHM at Hg 253,7nm)
Photometric(Abs): 0-550 (10mm equivalent)
Measurement Repeatability: 0.002(1mm path), or 1%CV, whichever is greater
Photometric Accuracy: ±2%(at 0.86A at 257 nm)
Limit of Detection: Pedestal: 2ng/µL dsDNA, 0.06mg/mLBSA, 0.03mg/mL lgG
Maximum Concentration: Pedestal: 27,500ng/µL dsDNA,820mg/mL BSA, 400mg/mL lgG
Measurement Time(S): ≤ 5
Cuvette Temperature(°C): 37±0.5
Cuvette Stirring: 10-900RPM 10 Speeds
Cuvette Photometric: 0-1.5A (10mm)
Cuvette Limit of Detection: 0.2ng/µL dsDNA 0.006mg/mL BSA 0.003mg/mL lgG
Display: 7 inch, 1280x800high-definition LCD,Multipoint capactive touch, Gesture recognition
Operating System: Android
Internal Storage: 32GB flash memory
PC Software Requirements: Windows 7:32/64 bit, Windows8/10:64 bit
Data transfer & PC connecting: USB, Wifi
Supply: AC110V-220V, 50Hz/60Hz(power adapter)
Net Weight: 2.3 Kg
mehr Large size color touch screen
Built-in 7-inch high-resolution color touch screen for more detection information, all operations can be done on the screen.
Wider detection range:
The 0.03 mm minimum detection path length, combined with a new generation of spectrometers, increases the maximum detection concentration to 27,500 ng/μL and the lowest detection concentration as low as 0.2 ng/μL dsDNA.
Vary models for your choice
According to different demands, you can choose different models of products, the full wavelength or the fixed wavelength, micro volume or cuvette, to meet the flexible detection needs. The cuvette module has a heating stirrer function.
Customizable wavelength
Built-in spectrometer, fixed wavelength model, can be upgraded to any wavelength configuration in the wavelength range according to your needs.
Light status prompt
The lighting strip around the test stand flashes with different states to show the detection process straightforwardly.
Android operating system
The machine has built-in operating system and detection software, without need a computer. Graphical touch operation is more in line with user friendly design and improves work efficiency.
Stable and reliable detection value
Both low concentration and ultra-high concentration of nucleic acid can be stably and accurately detected.
Specifications
Model: FC 3100
Detector: 2048-element CCD linear image sensor
Light Source: Xenon flash lamp
Minimum Sample Volume(µL): 0.5
Pathlength (nm) 0.03, 0.05, 0.1, 0.2, 1.0 auto-ranging
Wavelength Range(nm): 185-910
Wavelength Accuracy(nm): ±1
Spectral Bandwidth: ≤1.8(FWHM at Hg 253,7nm)
Photometric(Abs): 0-550 (10mm equivalent)
Measurement Repeatability: 0.002(1mm path), or 1%CV, whichever is greater
Photometric Accuracy: ±2%(at 0.86A at 257 nm)
Limit of Detection: Pedestal: 2ng/µL dsDNA, 0.06mg/mLBSA, 0.03mg/mL lgG
Maximum Concentration: Pedestal: 27,500ng/µL dsDNA,820mg/mL BSA, 400mg/mL lgG
Measurement Time(S): ≤ 5
Cuvette Temperature(°C): 37±0.5
Cuvette Stirring: 10-900RPM 10 Speeds
Cuvette Photometric: 0-1.5A (10mm)
Cuvette Limit of Detection: 0.2ng/µL dsDNA 0.006mg/mL BSA 0.003mg/mL lgG
Display: 7 inch, 1280x800high-definition LCD,Multipoint capactive touch, Gesture recognition
Operating System: Android
Internal Storage: 32GB flash memory
PC Software Requirements: Windows 7:32/64 bit, Windows8/10:64 bit
Data transfer & PC connecting: USB, Wifi
Supply: AC110V-220V, 50Hz/60Hz(power adapter)
Net Weight: 2.3 Kg
Optionen:
- F2100
Spectralphotometer µl Nano Ready Touch - F3100
Spectralphotometer µl NanoReady Touch - FC2100
Spectralphotomter µl plus cuvette NanoReady Touch with fixed wavelengths
Option von:
- F2100
Spectralphotometer µl Nano Ready Touch - F3100
Spectralphotometer µl NanoReady Touch - FC2100
Spectralphotomter µl plus cuvette NanoReady Touch with fixed wavelengths
- Artikel-Nr: FC-3100
- Warengruppe: Spektralphotometer
Alle Spektralphotometer von LabConsulting zeigen - Packung: 1 Stück
- Gültigkeit: 31.12.2024
- Letztes Update: 16.02.2024