PCR Cycler, Real Time, 2 x 8wells, 1 channel,
Die Abbildung kann abweichen und Zubehör enthalten, das sich nicht im Lieferumfang dieses Artikels befindet.
Artikelverweis:
- 3103010052
ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit, CE IVD - 3103010069
ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit 5.1, CE IVD - 90087RT
EliGene Covid19 Omicron RT kit - 90087RT500
EliGene Covid19 Omicron RT kit - A109090002
Magic Prep Fast Extraction Kits - SQ31B
iPonatic - Portable Molecule Workstation / 4 Module
Lieferzeit auf Anfrage
Bestell-Nr.: Q1601
Preis: Login Haben Sie Fragen ? Rufen Sie 0043 (01) 244 28 55 oder senden Sie ein mail !
Q1601, one channels and double 8-well blocks design, can run two different programs at the same time.
Small size, light weight, easy to carry.
Powerful software analysis function, which can be used for Quantitative Analysis, Melting Curve Analysis, Genotyping, etc.
-inch high-definition TFT color touch screen, and embedded win10 operating system.
20G flash memory can save 40,000 experimental data.
Printer as an optional which can print the records directly, no need to connect the computer.
Adopting side scan technology, the detection distance is close, and the fluorescence acquisition signal is stable;
Black reaction block to avoid background noise.
Adopt the same acquisition optical path to improve the repeatability.
LED light source has the advantage of energy saving, environmental protection, long service life and maintenance free.
Front shutdown button makes file data more secure.
Constant current control circuit makes power output smooth and extends Peltier life, also improves temperature control accuracy
It has the protection functions of over-current, over temperature, power-off data self recovery, etc.
Forward and backward air vent design, can be placed side by side, saving laboratory space.
It can be supported for battery power supply, suitable for quick inspection and field inspection.
Sample capacity: 16x0,2ml (2xBwell, doubleblock).
Consumable: Clear 0,2ml PCR tube/8-tubestrips.
Temperature control technology: Malow customized Peltier allow 1.000.000 cycles.
Temperature range: 0-100°C (Resolution: 0.1°C)
MAX.Ramp Rate: 6°c/s.
Temperature fluctuation: +-0.1°C.
Uniformity: +-0.25°C.
Accuracy: +.0.25°C.
Hot Lid Temperature: 30-115°C (adjustable, default 105°C).
Temperature Control: Blocl/Tube
Excitation wavelenght: 469-550nm.
Emission wavelenght: F1, 520-540nm.
Factory Calibrated Dyes: F1:FAM/SYBR Greenl.
Excitation: Long Life LED.
Detection: High sensitivity photoelectric detector.
Dynamic Range: 1-10^10.
Sensitivity: 1copy.
Feature Function: absolute/Relative Quantification, Meltingcurve, Genotyping.
Date Export Formats: excel, csv, txt.
Printing: Report can be printed (optional USB thermal printer).
Display: 7inch color TFT touch screen, 1280x800pels.
Communicatiopn Parts: 300x267x198mm(LxWxH)
Net wweight: 5,5kg
Power: DC15V250W
mehr Small size, light weight, easy to carry.
Powerful software analysis function, which can be used for Quantitative Analysis, Melting Curve Analysis, Genotyping, etc.
-inch high-definition TFT color touch screen, and embedded win10 operating system.
20G flash memory can save 40,000 experimental data.
Printer as an optional which can print the records directly, no need to connect the computer.
Adopting side scan technology, the detection distance is close, and the fluorescence acquisition signal is stable;
Black reaction block to avoid background noise.
Adopt the same acquisition optical path to improve the repeatability.
LED light source has the advantage of energy saving, environmental protection, long service life and maintenance free.
Front shutdown button makes file data more secure.
Constant current control circuit makes power output smooth and extends Peltier life, also improves temperature control accuracy
It has the protection functions of over-current, over temperature, power-off data self recovery, etc.
Forward and backward air vent design, can be placed side by side, saving laboratory space.
It can be supported for battery power supply, suitable for quick inspection and field inspection.
Sample capacity: 16x0,2ml (2xBwell, doubleblock).
Consumable: Clear 0,2ml PCR tube/8-tubestrips.
Temperature control technology: Malow customized Peltier allow 1.000.000 cycles.
Temperature range: 0-100°C (Resolution: 0.1°C)
MAX.Ramp Rate: 6°c/s.
Temperature fluctuation: +-0.1°C.
Uniformity: +-0.25°C.
Accuracy: +.0.25°C.
Hot Lid Temperature: 30-115°C (adjustable, default 105°C).
Temperature Control: Blocl/Tube
Excitation wavelenght: 469-550nm.
Emission wavelenght: F1, 520-540nm.
Factory Calibrated Dyes: F1:FAM/SYBR Greenl.
Excitation: Long Life LED.
Detection: High sensitivity photoelectric detector.
Dynamic Range: 1-10^10.
Sensitivity: 1copy.
Feature Function: absolute/Relative Quantification, Meltingcurve, Genotyping.
Date Export Formats: excel, csv, txt.
Printing: Report can be printed (optional USB thermal printer).
Display: 7inch color TFT touch screen, 1280x800pels.
Communicatiopn Parts: 300x267x198mm(LxWxH)
Net wweight: 5,5kg
Power: DC15V250W
- Artikel-Nr: Q1601
- Warengruppe: Thermocycler
Alle Thermocycler von LabConsulting zeigen - Schlagworte: PCR Geräte, Realtime PCR Cycler
- Gültigkeit: 31.12.2024
- Letztes Update: 16.02.2024
Alternative Artikel:
- GT48E
PCR Cycler Real Time, 4 Channel, Gradient - GT48R
PCR Cycler Real Time, 2 Channel, Gradient - GT96E
PCR Cycler Real Time, 6 Channel,Gradient - GT96R
PCR Cycler RealTime , 4 Channel, Gradient - GTMINI
PCR Cycler Real Time, 2 Channel, Gradient CE, IVD - Q1602
PCR Cycler Real Time, 2 x 8 well, 2 Channel - SLAN96P
PCR Cycler Real Time, SLAN 96P, 2x48 ,4 Channel